Physical performance:
|
|
|
|
|
|
|
Specific surface(m2/g)
|
|
|
|
Bulk specific weight(g/ml)
|
|
|
Normal technical condition and depuriating standards:
|
Operational pressure Normal:
|
pressure-3.0MPa
|
Operational temperature
|
10-50℃
|
Airspeed: (h-1)
|
500-1000h-1
|
The percentage of ammonia in the importing raw materials:
|
1~10PPm
|
The ratio between the height of bed and the column diameter:
|
>4
|
The content of ammonia in the exporting raw materials:
|
<0.5PPm
|
The penetration content of ammonia:
|
>5%
|
|
Note:
|
1.Condensate water must not be allowed to flow into the industrial raw materials , so as to prevent the loss of active constituent.
2.During the operation, sulfur removal must go before decarbonization.
3.The temperature of the charge gas should be kept at room temperature. It is bad for reaction to improve the temperature. |